Send Message
Home ProductsTelecom Rectifier System

Outdoor Data Cabinet Telecom Rectifier System

Certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
Customer Reviews
In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

The boxes are great we happy with it. We will order 30 sets each month in future. Cooperate Happily.

—— Andrej Sliachin

Always can provide us good suggestion and solution, we are very grateful.

—— Nelson

I'm Online Chat Now

Outdoor Data Cabinet Telecom Rectifier System

Outdoor Data Cabinet Telecom Rectifier System
Outdoor Data Cabinet Telecom Rectifier System Outdoor Data Cabinet Telecom Rectifier System Outdoor Data Cabinet Telecom Rectifier System Outdoor Data Cabinet Telecom Rectifier System

Large Image :  Outdoor Data Cabinet Telecom Rectifier System

Product Details:
Place of Origin: Shenzhen, China (Mainland)
Brand Name: ESTEL
Certification: ISO9001, CE, 3C, FCC, TLC
Model Number: GPE4860C
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiation
Packaging Details: carton/wooden case
Delivery Time: 7-10 working days
Payment Terms: L/C, D/A, D/P, , T/T, Western Union
Supply Ability: 10,000 sets per month
Detailed Product Description
Installation Mode: 19” Rack Output Power: 3200W
Input Voltage: AC220V Output Current: 60A
Power Factor: 0.98 Input Frequency: 45~65Hz
Application: Outdoor Telecom Cabinet
High Light:

telecom rectifier module

,

rack mount rectifier

 

Outdoor Data Cabinet Telecom Power Systems Low Power Consumption GPE4860C

 

Quick Details:

 

Place of Origin: Shenzhen, China (Mainland) Input Voltage: AC220V
Brand Name: ESTEL Output Voltage: DC48V
Model Number: GPE4860C Output Power: 3200W
Product Name: Telecom Power System Input Frequency 45~65Hz
Certification: ISO9001, CE, 3C, FCC, TLC Output Current: 60A
Installation Mode: 19” rack Power Factor: 0.98
Application: outdoor UPS cabinet

      Components:

      2×30A rectifier module,

      1×monitoring module,

      power distribution

 

Payment & Shipping Terms:

 

Minimum Order Quantity: 1 set
Price: negotiation
Payment Terms: L/C, D/A, D/P, , T/T, Western Union
Supply Ability: 10,000 sets per month
Delivery Time: 7-10 working days
Packaging Details: carton/wooden case

 

1. System Configuration

 

The system consists of distribution unit, rectifier module (up to 2 sets) and 1 monitoring module. The configuration is optional, as following table:

 

Configuration Rectifier Module Monitoring Module Distribution
Standard GPR4830A/B GPM48M

DC output:

40A×1 (Load);

Battery output: 40A×1 (Battery)

 

2. Operating Principle

 

Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).

 

Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding. When the operating temperature is 55°C or more, power de-rating will be employed by system.

 

3. System Properties

 

Input
Parameter Min. Typical Max. Unit Remark
Input voltage range 90 220 285 Vac Nominal operating voltage: 100V-240V
Input frequency 45 50 65 Hz  
Inrush current     50 A

Cold start @ 25°C, 285 Vac input

Tested at full load

Power factor 0.98        

 

Output
Parameter Min. Typical Max. Unit Remark
Output voltage rating   -53.5   Vdc  
Output voltage range -43.2 -53.5 -57.6 Vdc  
Output current range 0   60 A 176~285VAC
Ripple (Vp-p)     200 mv After 1-hour operation at low temperature, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz, with 20CM twisted pair.
Output efficiency 90     % 220Vac input, rated output
82     % 110Vac input, 15A output
Regulation     ±2 %  
Load regulation     ±2 %  
Line regulation     ±1 %  
Output power     3200 W 176-285V Input
    1200 W 90-175V Input

 

Insulation rating
Parameter Requirement Remark
Input - output 3500Vdc/10mA//1min No flashover and breakdown, with discharge tube removed.
Input-chassis 3500Vdc/10mA//1min
Output - chassis 750Vdc/10mA//1min
Leakage current ≤3.5mA  
Insulation resistance At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ

 

Ambient requirements
Parameters Min. Typical Max. Unit Remark
Nominal operating temp -15 25 +55 °C  
Operating temp -33   +55 °C Start up with full load at -40°C, normal operation, with partial degradation of performance permissible. For temperature between 55°C and 65°C, output with derating to 80%
Storage tempStorage temperature -40   +70 °C  
Relative humidity 5   95 % Long-term operation, no condensing
Atmospheric pressure 70   106 KPa  
Altitude 0   4000 m  
Cooling method Forced cooling, front-in & rear-out, the fan is located inside the front panel, with speed programmable by the temperature.
Ingress protection The unit can operate when the diameter of dust particle is more than 5µm, with density ≤3*104 /m3. The dust shall not be conducting, electromagnetic or corrosive.

 

Mechanical specifications
Dimensions (Overall) 442mm×250mm×43.6mm
Weight(kg) (Overall) ≤7Kg(including modules)

 

Outdoor Data Cabinet Telecom Rectifier System 0

4. Electric Connection

 

Chassis connects with external electric through system interface board. As shown in figure below:

 

Outdoor Data Cabinet Telecom Rectifier System 1

 

1. Bracket 2. AC input socket with three-core

3. Rectifier module 4.Monitoring module

5. Signal interface 6. Output connectors

 

5. Application

 

(1) Small scale program controlled exchanger

(2) Access network

(3) Transmission equipment

(4) Mobile communication

(5) Satellite communication ground station

(6) Microwave communication

 

6. Features

 

(1) Adoption of active power factor compensation technology with factor >0.98

(2) Wide operating range of AC input voltage: 90~285Vac

(3) Operating temperature range:-33°C~+55°C

(4) Zero current/voltage switching tech with high efficiency ≥90%

(5) Perfect battery management, battery temperature compensation, LVLD and LVBD protection, battery capacity test

(6) Hot-swappable

(7) Input over/under voltage protection

(8) Output over voltage protection

(9) Output over current protection

(10) Output short circuit protection

(11) Auto current sharing, parallel operation

(12) Embedded mounted

(13) Multiple communication ports, easy for networking and remote management

 

7. Packing and Shipping


Outdoor Data Cabinet Telecom Rectifier System 2


Our Delivery Agent

The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.

Outdoor Data Cabinet Telecom Rectifier System 3

8. Our Contact Information

Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941

Email: info@estel.com.cn

           lxf.estel@hotmail.com
Skype: fiona.liang10

 


9. Our Partner

Outdoor Data Cabinet Telecom Rectifier System 4

Contact Details
Tianjin Estel Electronic Science and Technology Co.,Ltd

Contact Person: Fiona Liang

Tel: 86-13752765943 / 86-0755 23592644

Send your inquiry directly to us (0 / 3000)