Send Message
Home ProductsTelecom Rectifier System

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP

Certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
China Tianjin Estel Electronic Science and Technology Co.,Ltd certification
Customer Reviews
In the past three years, our cooperation is very cheerful, thanks for your company's technical support and patient service, the end user is very satisfied with the quality of outdoor telecom cabinet with cooling. Best wishes to our future cooperation.

—— Anthony

Timely response, professional skills, rigorous attitude, fast delivery, we are very satisfied, cooperation is very smooth.

—— Manish

From 1 sample to 45 sets, 76 sets, 200sets, we gradually established a strong trust. The cabinet quality is good and the design is reasonable.

—— Parmar

The air conditioner have been running for one and a half years. Cooling effective is good. Good after-sale service, and patiently instruct to use and solve technical problems. Environmental monitoring system is also running well, and remote monitoring the cabinet is very convenient.

—— Luis Alberto

The boxes are great we happy with it. We will order 30 sets each month in future. Cooperate Happily.

—— Andrej Sliachin

Always can provide us good suggestion and solution, we are very grateful.

—— Nelson

I'm Online Chat Now

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP
19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP

Large Image :  19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP

Product Details:
Place of Origin: Shenzhen, China (Mainland)
Brand Name: ESTEL
Certification: ISO9001, CE, 3C, FCC, TLC
Model Number: ET48700P300
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: Negotiation
Packaging Details: Wooden case
Delivery Time: 15-20 working days
Payment Terms: L/C, D/A, D/P, MoneyGram, T/T
Supply Ability: 3,000 sets per month
Detailed Product Description
Name: Rack Mount Telecom Rectifier Type: Telecom Power Supply For Outdoor Cabinet
Rectifier Module: 3KW×14pcs Solar Module: 3KW×6pcs
Controller: Ethernet , SNMP, ModBus And RS485 Communication Installation Mode: 19 Inch Rack
Dimention(W×D×H): 482×350×15U Input Voltage: 380VAC Three Phase
Output Voltage: -48VDC (-42 To -58VDC) Module: Hot-swappable
Module Efficiency: ≥ 96% Battery Management: Support
Load Breakers: Customized Battery Breakers: Customized
High Light:

48V DC Power Supply Telecom

,

19 Inch Telecom Rectifier System

,

Rack Mounted Rectifier 48V

 

19 Inch Rack Mount 42KW 48VDC Telecom Power Supply Telecom Rectifier 18KW Solar Module SNMP
 

 

1. Rack Mount Telecom Rectifier Overview

 

 

ET48700P300 is a 19-inch sub-rack for hybrid telecom power supply system , with 15U height compact design to meet critical application needs of fiber and microwave transmission, access device, switch.


The system’s maximum power is 700A, with AC input/DC input/battery/load MCBs. The cables are front accessing with MCB and busbar. This power system supplies power to -48VDC communication equipments.

 

 

2. Telecom Rectifier System Parameter

 

Model ET48700P300
System Dimension(mm) 482.6(W)x350.6(D)x15U(H)
  Weight ≤ 50kg(without rectifier module)
  Cooling mode Forced air cooling
  Installation mode Installed on 19-inch rack or inside the cabinet
  IP Grade IP20
AC Distribution Input voltage

380VAC, three phase

  Input capacity 1x125A/4P
  Input frequency 45~65Hz, rated 50/60Hz
  AC SPD 20kA/40kA, 8/20μs
  PV Input capacity 6x63A/2P

DC Distribution

Output voltage -42~-58VDC, rated value: -53.5VDC
  Maximum capacity 42kW(14x3000W rectifier module)
  Battery breakers

3x125A/3P

  Load breakers

LLVD: 2x125A/1P, 2x63A/1P

BLVD: 2x125A/1P, 2x63A/1P

  DC SPD 10kA/20kA, 8/20μs(designed inside)
PV Module Input voltage

120VDC to 425VDC, rated value: 340VDC

  Efficiency ≥96%
  Output power

3000W(200~425VDC)

  Dimension 106.5mm(W)×286mm(D)×41.5mm(1U/H)
  Cooling mode Forced cooling with fan
Rectifier Module Input voltage 85VAC-300VAC, rated value: 220VAC
  Efficiency ≥96%
  Rated power 3000W(176~300VAC )
  Dimension 106.5mm(W)×286mm(D)×41.5mm(1U/H)
  Cooling mode Forced cooling with fan
Controller Signal input 3 AI(2 battery temp., 1 ambient temp) ,7 DI(SPD, 6 common DI)
  Alarm output 6 dry contact
  Communication port RS485/LAN Ethernet/SNMP
  Display mode LCD

Environment

Operating temperature

-40℃~+65℃
  Storage temperature -40℃~+70℃
  Operating humidity 5%~95%(non-condensing)
  Altitude 0~3000m(If the altitude is within the range of 2000m to 3000m, the maximum operating temperature decreases by 1℃ as the altitude increases by 200m.)

 

 

3. Telecom Rectifier Quick Details 

 

Consists of distribution unit, rectifier module, photovoltaic module, monitoring module. The configuration is optional, quick details as below:

  • Rectifier module: 3kwx14
  • Photovoltaic module: 3kwx6
  • Battery breakers: 3x125A/3P
  • Load breakers: LLVD: 2x125A/1P, 2x63A/1P; BLVD: 2x125A/1P, 2x63A/1P 
  • Solar breakers: 6x63A/2P
  • Controller: RS485/LAN Ethernet/SNMP

 

Pictures 

 

Load/battery breakers:

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 0

 

 

Photovoltaic module breakers: 

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 1

 

 

Telecom rectifier system pictures:

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 2

 

 

19 inch rack mounted telecom power supply pictures:

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 3

 

Telecom power supply production line: 

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 4

 

 

4. Telecom Rectifier Working Principles

 

(1) Figure Conceptual Diagram shows the conceptual diagram. DC power enters solar module through the DC power distribution unit (PDU).

The solar module converts high-voltage into -48VDC. AC power enters rectifiers through the AC PDU.The rectifiers convert the AC power

input into -48VDC power output, which is directed by the DC PDU to DC loads along different routes.

 

(2) During normal operation, the solar module priority to the DC load and charging batteries. When the solar power is low, the AC power , rectifiers power DC loads and charge batteries. When both the AC and solar are absent, rectifiers and solar modules stop working and

batteries start to power loads. After the AC or solar power power resumes, rectifiers or solar module power DC loads and charge batteries again.

 

(3) The monitoring unit monitors the running state of each component of the telecom power supply system in real time, and carries out the corresponding intelligent control. When detecting a fault, the monitoring module generates an alarm.

 

 

Figure Conceptual Diagram:

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 5

 

 

5. Telecom Rectifier Configuration Table

 

 

Item Configurations
Subrack

3U AC input power distribution space

3U DC input power distribution space

3U DC output power distribution space

6U Module installation and monitor unit space

The power distribution unit

AC/DC input power distribution: AC input MCB, DC input MCB

DC power distribution:

battery low voltage disconnection (BLVD) route, load low voltage

disconnection (LLVD) route, and battery route

Monitor unit MC2600
Rectifier module A maximum of fourteen 3000W 
Solar module A maximum of six 3000W
AC SPD Class C
DC SPD PV Input:Class C
48V Output:Class D

 

 

6. Details of Rectifier Module And Solar Module

 

 

(6.1) The module panel

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 6

                             (1) Power indicator         (2) Alarm indicator      (3) Fault indicator

                             (4) Locking latch             (5) Handle

 

 

There are three indicator on the panel,which are used to reflect the operation status of the rectifier,see Table below for details.

 

Indicator Color Status Reasons for abnormal status
Power indicator Green Normally on The module has and power input
Off Main supply fault(no power input or OVP,UVP of power input).non-output
Alarm indicator Yellow Normally on Temperature alarm(OTP when the ambient temperature>65℃)
The module is hibernating. (indicator lighting, no alarm)
The module is current-limiting
Flickering Communication failure

Fault

indicator

Red Normally on

Non-output caused by module inner reason such as OVP, fan

fault, OTP

Normally off The module is running properly.

 

 

(6.2) Solar Module Model MS483000HG Discription

 
Input Characteristics
Input Voltage Range
120VDC to 425VDC(power-up voltage is above 160VDC)
Rated Input Voltage 340VDC
MPPT Voltage Range 120VDC to 340VDC
Maximum Input Current 17A
Surge Current Standard: EN/IEC61000-4-5
MPPT Precision ≥99%@load≥400W
Reverse Polarity Protected
no damage even with the wrong polarity
Input Fuse
fuse both on the positive & negative polarities
Maximum Input Voltage 450VAC(power good)

 

Output Characteristics
Output Voltage
+54.5VDC
Output Voltage Setting Value
+54.5±0.1VDC
Adjustable Output Voltage Range
+42VDC~+58VDC
Efficiency
≥96%@340VDC/40%~70% Load- 54.5VDC
Source Effect
±0.1%
Load Effect
±0.5%

 

 

(6.3) Rectifier Module Model MR483000HG2B-GS Discription

 

AC Input Characteristics
Operating Voltage
85VAC to 290VAC
Frequency
45Hz-66Hz
Rated value is 50Hz/60Hz
Input Current
≤ 18A
Power Factor

≥0.99 ( 220VAC@20%-100% load )

THD ≤5% ( 50%-100% load )

 

 
Output Characteristics
Output Voltage

42V DC-58V DC

Rated Value is 53.5 V DC

Linear Power Derating

3000W (176V AC-290V AC)

3000W-1250W (175V AC-85V AC)

Regulated Voltage Precision ≤±0.6% Vo
Ripple and Noise
≤200mVp-p(bandwidth≤20MHz)
Standby power
≤4W
Startup duration
3s~8s(Instant start mode)
Output hold-up time
>10ms
Phone noise weighting voltage
≤2mV
Wide-band noise voltage
50mV(3.4kHz~150kHz)
≤20mV(0.15MHz~30MHz)

 

 

(6.4) Communication between Rectifier/Solar Module & Monitoring Module

 
CAN-bus communication mode is adopted between the rectifier/solar module and the monitoring module. Remote software version upgrade is supported, and the address of the module can be set through the address board. When AC input disconnects, the module needs to communicate with the host.
 
Isolation design is employed for CAN interface in the rectifier module. The power supply of CAN is +5VDC, which is provided by the rectifier/solar module internally.
 
The main monitoring information of the rectifier/solar module is as below:
1) Voltage regulation and current regulation functions: meeting the requirements of floating charging battery and voltage regulation;
2) Single module control of startup and shutdown;
3) Protection and Alarm Information Feedback:
  •     Mains fault: mains fault (AC input over-voltage/under-voltage);
  •     Module protection: temperature pre-alarm;
  •     Module fault: fan fault, over temperature shutdown or no output caused by the module internally; (the module is in the state of dormancy and shutdown, and the mains failure is not reported to the module).

 

7. Controller-MC2600 (Monitoring Module)

 

The MC2600 front panel

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 7

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 8

 

 

                (1) LAN port     (2) RS485 port    (3) Run indicator       (4) Minor alarm indicator

                (5) Major alarm indicator             (6) Handle                 (7) Buttons

 

 

Table for controller button description

 

Button Description
ESC

Returns to the previous menu without saving the settings.

Press the ESC and ENT button at the

same time within a short period of

time can restart the controller.

ENT.

 

Ø Enters the main menu from the standby

screen.

Ø Enters a submenu from the main menu.

Ø Saves the menu settings.

UP

Turns to the previous menu or sets parameter values.

When setting parameter values, you can hold down this button to quickly adjust values.

When the parameter value is set by

multiple string types, press up or

down button to change each value.

After setting the value, press the

confirm button to move the cursor

back automatically.

DN.

Turns to the next menu or sets parameter values.When setting parameter values, you can hold down this button to quickly adjust values.

 

Describes the indicator on the controller panel is shown in table below

 

Type Color State Instructions
Run indicator Green Flickering Controller is running properly
Off Controller is fault or has no DC input
Minor Alarm Yellow Normally on The controller generates a minor alarm
Off The controller does not generate any minor alarms
Major alarm Red Normally on The controller generates a major alarm
Off The controller does not generate any major alarms


 

The controller provides two communication ports

 

The definition of RS485 communication port is shown in below table

 

Pin No. 1 2 3 4 5 6 7 8
Signal name RS485+ - RS485- - - - - -

 

 

 

 

The LAN Ethernet port interface definition is shown in Table

 

Pin No. 1 2 3 4 5 6 7 8
Signal name TX+ TX- RX+ - - RX- - -

 

 

 

 

 

8. DI/DO Interface

 

The DI/DO interface board front panel

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 9

 

Digital input is submenu of parameter setting menu, which is mainly used for the operator to configure the input normal state of 8 digital switches in the system.

 

Table - Relay input parameter setting

 

Digital No. Digital name DI Normal Description
DI1 HEX Alarm NO It is normal when opened; and the alarm occurs when closed.
DI2

PWC Door Alarm

NC It is normal when opened; and the alarm occurs when closed.
DI3 BT Alarm NO It is normal when opened; and the alarm occurs when closed.
DI4 BC Alarm NO It is normal when opened; and the alarm occurs when closed.
DI5 Digital5 Alarm NO It is normal when opened; and the alarm occurs when closed.
DI6 Genset on Alarm NO It is normal when opened; and the alarm occurs when closed.

DI7

DC SPD Alarm

NC

It is normal when opened; and the alarm occurs when closed.

 

 

Relay output is submenu of parameter setting menu, which is mainly used for the operator to configure the output normal state of 8 relays in the system.

 

Table - Relay output parameter setting

 

Digital No. Digital Name Alarm code Description
DO1 Relay output 1 NC Closed when normal,opened when associated alarm occurs.
DO2 Relay output 2 NC Closed when normal,opened when associated alarm occurs.
DO3 Relay output 3 NC Closed when normal,opened when associated alarm occurs.
DO4 Relay output 4 NC Closed when normal,opened when associated alarm occurs.
DO5 Relay output 5 NC Closed when normal,opened when associated alarm occurs.
DO6 Relay output 6 NC Closed when normal,opened when associated alarm occurs.

 

In addition, the product provides 6 other ports.

 

Table - Other intput parameter setting

 

Parameter name Setting description
BTEMP 1 Battery sensor1 port
BTEMP 2 Battery sensor2 port
ENV_TEMP Enveropment sensor port
12V +/- 12V power supply is provided
RS485 RS485 port, reserved interface, no protocol definition
OIL+/- Connect the oil level sensor

 

 

 

9. Install Subrack

 

Install the subrack to the 19-inch rack, as shown in Figure below.

 

Ø Step 1,Remove the plug from the package.

Ø Step 2,Push the plug into the 19-inch rack

Ø Step 3,Install the fixed screw (if the mounting hole of the plug frame ear does not correspond to the position of the floating nut of the frame,

it needs to be adjusted according to the actual installation).

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 10

 

 

Install Rectifier/Solar module

 

Ø Step 1, Take out the module from the package.

Ø Step 2, Hold the module handle on the front panel and put the module onto the slot.

Ø Step 3, Push the module slowly to the front panel of the module and flush with the power

distribution panel.

Ø Step 4, Tighten the fixing screw on the module panel so that the module does not come off.

 

 

 

 

19 Inch Rack Mount 48V DC Power Supply Telecom Rectifier System Solar Module SNMP 11

 

10. Packing and Shipping

 

Package use free fumigation woodcase which is suitable for export. This package is anti moisture, anti impact and srong to ensure safe transportation.

 

 